> 상품 >
DX 코일 공기 처리 장치 AHU
>
Holtop DC Inverter Air Conditioners DX Coil Air Handling Units 9000 m³/h

Holtop DC Inverter Air Conditioners DX Coil Air Handling Units 9000 m³/h

제품 상세정보:
원래 장소: 베이징,중국
브랜드 이름: Holtop
인증: CE
모델 번호: HZN-18KCZ1-Y-DC-BZ & HFM-18ha1-DC
상세 정보
원래 장소:
베이징,중국
브랜드 이름:
Holtop
인증:
CE
모델 번호:
HZN-18KCZ1-Y-DC-BZ & HFM-18ha1-DC
실내 유닛 모델:
HZN-18KCZ1-Y-DC-BZ
실외기 모델:
HFM-18HA1-DC
공칭냉방능력(kw):
40.4
공칭난방용량(kw):
45.4
전원공급장치:
380V/3PH/50Hz
실내기 풍량(m³/h):
9000
실내기 ESP(Pa):
360
실외기 냉각전원 입력(KW):
11.61
실외기 실외기(KW):
12.93
냉각제:
R410A
강조하다:

High Light

강조하다:

Holtop DC inverter air conditioner AHU

,

DX coil air handling unit 9000 m³/h

,

Holtop air handling unit with warranty

거래 정보
최소 주문 수량:
1개
가격:
협상 가능
포장 세부 사항:
상자
배달 시간:
2주
지불 조건:
TT
공급 능력:
연간 200000 단위
제품 설명
Holtop DC Inverter Air Conditioners DX Coil Air Handling Units 9000 m³/h
Product Overview
Adopt a number of leading technologies to build a more powerful, stable and efficient cooling system. Innovative noise reduction technology minimizes the operating noise of indoor and outdoor machines and creates a quiet environment. New shell design provides better stability and improved appearance.
Holtop DC Inverter Air Conditioners DX Coil Air Handling Units 9000 m³/h 0
Holtop DC DX Air Handling Unit includes DC Inverter DX air conditioner outdoor unit and constant frequency DX air conditioner outdoor unit these two series. The capacity of DC inverter DX AHU is 10-20P, while the capacity of constant frequency DX AHU is 5-18P.
On the basis of constant frequency DX AHU, the newly developed DC inverter DX AHU adopts the enhanced vapor injection technology to open a new era of low-temperature heating. The new design of air-conditioning system and self-developed control program give full play to product performance and bring users a more comfortable air-conditioning experience.
Technical Specifications
Item/Series DC Inverter Series Constant Frequency Series
Cooling capacity (kw) 25 - 509 12 - 420
Heating Capacity (kw) 28 - 569 18 - 480
Airflow (m³/h) 5500 - 95000 2500 - 80000
Frequency Range of Compressor (Hz) 20 - 120 /
Max. length of Pipe (m) 70 50
Max. Drop (m) 25 25
Operating Range Cooling
Outdoor DB temperature (°C): -5-52 Outdoor DB temperature (°C): 15 - 43
Heating
Indoor DB temperature (°C): 15 - 27
Outdoor WB temperature (°C): -20 - 27
Indoor DB temperature (°C): 10-27
Outdoor WB temperature (°C): -10-15
Indoor Unit Features
Heat Exchangers
There are cross-flow total heat exchangers, cross-flow plate heat exchangers or rotary heat exchangers to choose from to meet the different needs of customers.
Holtop DC Inverter Air Conditioners DX Coil Air Handling Units 9000 m³/h 1
PM2.5 Filtration Solution
High Efficiency To Remove The Haze
Equipped with a high-efficiency filter element, which can effectively remove PM2.5 particles carried in the air, ensuring that the outdoor air entering the indoor air is clean.
Holtop DC Inverter Air Conditioners DX Coil Air Handling Units 9000 m³/h 2
Indoor Formaldehyde Removal Solution
The indoor unit can be added with a formaldehyde removal module to effectively filter and decompose formaldehyde molecules; coupled with the replacement and dilution of heat exchangers and filters, double removal of formaldehyde.
Holtop DC Inverter Air Conditioners DX Coil Air Handling Units 9000 m³/h 3
Fresh Air Supply
With this AHU, fresh outdoor air will be brought into the room. By increasing the oxygen concentration, reducing carbon dioxide, removing odors and other harmful gases, the indoor air quality is greatly improved.
Outdoor Unit Features
Top Discharge Outdoor Unit
Structural features of the top discharge outdoor unit
Holtop DC Inverter Air Conditioners DX Coil Air Handling Units 9000 m³/h 4
Side Discharge Outdoor Unit
Structural features of side discharge outdoor unit
Holtop DC Inverter Air Conditioners DX Coil Air Handling Units 9000 m³/h 5