Home > products >
Combine Air Handling Units AHU
>
Hospital Digital Intelligent Fresh Air Ventilation System

Hospital Digital Intelligent Fresh Air Ventilation System

Product Details:
Place of Origin: Beijing,China
Brand Name: Holtop
Certification: CE
Model Number: Hospital Digital Intelligent Fresh Air Ventilation System
Detail Information
Place of Origin:
Beijing,China
Brand Name:
Holtop
Certification:
CE
Model Number:
Hospital Digital Intelligent Fresh Air Ventilation System
Product Name:
Hospital Digital Intelligent Fresh Air Ventilation System
Colour:
White
Feature:
Low Noise
Application Scenario:
Hospital
Place Of Origin:
Beijing, China
Highlight:

High Light

Highlight:

packaged ahu chiller

,

Ventilation ahu chiller

,

Ventilation packaged air handler

Trading Information
Minimum Order Quantity:
1pc
Price:
Negotiable
Packaging Details:
box
Delivery Time:
Two weeks
Payment Terms:
TT
Supply Ability:
200000 units per year
Product Description

      Holtop proposes that the hospital system solution is a systematic project to help customers solve problems, that is, different hospitals have different solutions. Even if the same medical equipment is used and designed by the same design company, the ring will be based on the actual situation of the hospital. The situation provides the only solution that fully and completely considers the needs of the hospital’s on-site medical equipment, operation and future development, and is customized for customers.


Products Detail


      Requirement for Ventilation of Hospital

      The internal ventilation of hospital needs independent area control, different areas need different        ventilation, and the airflow control is more complicated. In general, there are four principles:

Fresh air is introduced from the outdoor or clean area, enters the semi-polluted area, and then enters the polluted area through the pressure difference until it is discharged outdoors, effectively avoiding backflow. Meet the fresh air demand of health hospital staff and patients. At the same time, consider factors such as air exchange rate and air pressure difference in the polluted area to ensure that the fresh air flow is very sufficient.
Maintain the continuity of the 24-hour fresh air supply, pay more attention to the air flow in the hospital, and continue to maintain air quality. By monitoring the air quality and automatically adjusting the fresh air and exhaust air intelligently according to the air quality sensor, each room can be controlled individually or by the master control system, saving energy and time to the greatest extent.


      Ventilation Requirement in Different Areas of Hospital


Hospital Digital Intelligent Fresh Air Ventilation System 0

Hospital Digital Intelligent Fresh Air Ventilation System 1


Digital Intelligent Fresh Air Ventilation System

      Whether the system design is complete and the function configuration is reasonable will directly affect the efficiency of the entire system. At the same time, it will also have a great impact on the front-end investment and operating costs. Therefore, Holtop will select projects based on high standards, high performance, high configuration, and low cost.


Hospital Digital Intelligent Fresh Air Ventilation System 2


Hospital Digital Intelligent Fresh Air Ventilation System 3


      According to the characteristics of different types of buildings and the needs of users, ventilation systems of different forms and different economic standards can be designed.


      For example, in a hospital ventilation system that is usually divided into clean, semi-polluted, and contaminated areas, the stepwise air pressure should be differentiated in each area to control the flow of air from the clean area to the polluted area and prevent the free spread of high-risk air.


Hospital Digital Intelligent Fresh Air Ventilation System 4