Home > Products >
Industrial Air Handling Units AHU
>
Hot Sale For Holtop Vortex Module-Type Air-Cooled Chilled Water (Heat Pump) Unit HFW-840HA1

Hot Sale For Holtop Vortex Module-Type Air-Cooled Chilled Water (Heat Pump) Unit HFW-840HA1

Product Details:
Place of Origin: China,Beijing
Brand Name: Holtop
Certification: CE
Model Number: HFW-840HA1
Detail Information
Place of Origin:
China,Beijing
Brand Name:
Holtop
Certification:
CE
Model Number:
HFW-840HA1
Model:
HFW-840HA1
Nominal Cooling Capacity(kw):
848.0
Nominal Heating Capacity(kw):
908.0
Nominal Refrigeration Input Total Power(kw):
258.4
Nominal Heating Input Total Power(kw):
264.8
Power Supply:
380V/3N~/50Hz
Fan Type:
Axial-flow Low-noise Fan
Refrigerant Type:
R410A
Dimension(mm):
7080*2280*2540
Net Weight(kg):
8040
Gross Weight (kg):
8320
Highlight:

High Light

Highlight:

Holtop Vortex air-cooled chiller unit

,

Module-type chilled water heat pump

,

Industrial AHU water cooling system

Trading Information
Minimum Order Quantity:
1pc
Price:
Negotiate
Packaging Details:
Carton
Delivery Time:
Negotiate
Payment Terms:
T/T
Supply Ability:
20000PCS/years
Product Description
Holtop Vortex Module-Type Air-Cooled Chilled Water (Heat Pump) Unit HFW-840HA1
The vortex module-type air-cooled chilled water (heat pump) unit utilizes advanced modular technology with air as the cooling and heating medium. This integrated central air conditioning equipment serves as both a cooling/heating source and combined unit. It can be paired with fan coil units, cabinet-type air handlers, ceiling-mounted air handling units, and fresh air units to create efficient semi-centralized air conditioning systems.
Key Product Features
  • Modular Combination & Hierarchical Startup: Modular design allows flexible combinations without distinguishing between main and secondary machines. Supports up to 16 units per group with hierarchical startup to reduce current impact on power grids.
  • Intelligent Defrosting: Multi-variable detection for precise frost determination and optimal defrost timing. Dual-system design enables interval defrosting with manual override capability in harsh conditions.
  • Flexible Application: Easy unit expansion suitable for phased investment. Compact design allows independent transportation and installation without large equipment. End water inlet/outlet design reduces installation space requirements.
  • Safe Operation Control: Comprehensive safety protection functions with intelligent multi-variable monitoring for efficient and stable operation.
  • Fault Backup Operation: Dual-compressor design ensures continued operation if one compressor fails, maintaining system functionality.
Technical Specifications
Rated Voltage Three-phase 380V/3N~
Rated Frequency 50Hz
Power Supply Voltage ±10% of rated voltage
Operating Conditions See operating range tables
Storage Conditions Environmental temperature: -28 to 85℃
Control Method Remote controller
Fan Type Axial flow low-noise fan
Operating Range
Operating Condition Outdoor Ambient Temperature Outlet Water Temperature
Cooling 15℃ ≤ Temperature ≤ 48℃ 5℃ ≤ Temperature ≤ 15℃
Heating -15℃ ≤ Temperature ≤ 21℃ 40℃ ≤ Temperature ≤ 50℃
Refrigeration System Performance Parameters
Outlet Temperature (℃) Environment Temperature (℃)
25 30 35 40 45
51.071.000.940.840.81
61.101.030.970.870.83
71.141.071.000.910.86
81.171.101.030.940.88
91.201.131.060.980.91
101.231.161.091.010.93
111.271.191.121.040.96
121.311.231.151.070.99
131.341.261.171.091.01
141.371.291.201.121.03
151.411.321.231.141.06
Heating Mode Performance Parameters
Outlet Temperature (℃) Environment Temperature (℃)
15 10 7 0 -5 -10
301.231.101.030.940.880.75
351.211.091.020.930.870.75
401.201.081.010.910.850.74
451.191.071.000.900.840.74
501.171.050.980.850.800.74
Large Vortex Modular Air-Cooled Chiller (Heat Pump) Unit Models
Model HFW-420HA1 HFW-560HA1 HFW-840HA1 HFW-980HA1 HFW-1120HA1
Nominal Cooling Capacity (kW) 420.0 560.0 840.0 980.0 1120.0
Nominal Heating Capacity (kW) 454.0 605.0 908.0 1059.0 1210.0
Refrigeration Input Power (kW) 129.2 172.3 258.4 301.5 344.6
Heating Input Power (kW) 132.4 176.4 264.8 308.8 352.8
Compressor Quantity 3 4 6 7 8
Fan Power (kW) 1.8x6 1.8x8 1.8x12 1.8x14 1.8x16
Nominal Water Flow Rate (m³/h) 72.2 96.3 144.4 168.5 192.6
Dimensions LxWxH (mm) 3540x2280x2540 4700x2280x2540 7080x2280x2540 8240x2280x2540 9400x2280x2540
Weight (kg) 4020/4160 5350/5540 8040/8320 9370/9700 10700/11080
Important Notes:
1. Nominal cooling capacity test conditions: water flow rate 0.172 m³/(h*kW), outlet water temperature 7°C, outdoor ambient temperature 35°C.
2. Nominal heating capacity test conditions: water flow rate 0.172 m³/(h*kW), outlet water temperature 45°C, outdoor dry/wet bulb temperature 7/6°C.
3. Total water pipe for modular combinations requires on-site fabrication and installation.
4. Modular units can be combined from 1 to 16 units using same or different models as needed.
5. Control accessories including remote controller, user manual, and connection cables must be ordered separately.