Haus > produits >
Residential ERV HRV
>
Air Temperature Sensor And Residential ERV HRV equipment engineered to optimize indoor air exchange and reduce energy waste in residential buildings

Air Temperature Sensor And Residential ERV HRV equipment engineered to optimize indoor air exchange and reduce energy waste in residential buildings

Produktdetails:
Herkunftsort: China
Markenname: HOLTOP
Zertifizierung: CE
Modellnummer: CFA350C
Ausführliche Information
Herkunftsort:
China
Markenname:
HOLTOP
Zertifizierung:
CE
Modellnummer:
CFA350C
Nennspannung/Frequenz:
1Ph 120V~60Hz
Stromversorgungsspannung:
Nennspannung ±10 %
Betriebsbedingungen:
Temperatur: 14–113 °F (-10–45 °C); relative Luftfeuchtigkeit: unter 85 % relative Luftfeuchtigkeit
Lagerbedingungen:
Temperatur: -20 bis 55 °C; relative Luftfeuchtigkeit: unter 85 % relative Luftfeuchtigkeit
Motortyp:
Gleichstrommotor mit Kunststoffkapselung
Wärmetauscher:
Rahmen aus Kunstharz
Filter:
G3 PU-Rahmen
Lüfterradtyp:
Nach vorne gebogene Klingen
Hervorheben:

High Light

Hervorheben:

Residential ERV HRV air exchange system

,

Air temperature sensor for ERV HRV

,

Energy efficient residential ERV HRV equipment

Handelsinformationen
Min Bestellmenge:
1 PCs
Preis:
Verhandlungsfähig
Verpackung Informationen:
Box-Paket
Lieferzeit:
Zwei Wochen
Zahlungsbedingungen:
T/T
Versorgungsmaterial-Fähigkeit:
200.000 Einheiten pro Jahr
Produkt-Beschreibung
Air Temperature Sensor And Residential ERV HRV Equipment
Product Overview

Engineered to optimize indoor air exchange and reduce energy waste in residential buildings with intelligent electrical control features.

Hardware Configuration
Basic Hardware
  • 1 fresh air inlet temperature sensor
  • 1 supply air outlet temperature sensor
  • 1 return air temperature sensor
Optional Hardware
  • 1 external humidity sensor
  • 1 external CO2 sensor
  • 1 external differential pressure switch
  • 1 WiFi module
Customer-Supplied Hardware
  • 2 external electric heaters
Hardware Interfaces Reserved for Customer
  • 2 RS485 communication ports: 1 for centralized control to external system, 1 for communication between master and slave boards
  • 4 digital inputs reserved: Fire alarm signal input, bypass control switch, forced start switch, differential pressure signal input, forced high-speed signal input
  • 4 digital outputs reserved: Operation status signal output, fault signal output, electric heater 1 output, electric heater 2 output
Standard Keypad Controller Functions (HDK-CK23C2)
Basic Functions
  • Heat Exchange Mode: Energy from exhaust air can be extracted to heat (in winter) or cool (in summer) the fresh air, reducing energy consumption
  • Speed Adjustment: 5 adjustable speeds (positions 1, 3, 5, 7, 10) for supply air and exhaust air outlets, adjustable independently
  • Operation Timer: Unit can operate intermittently for 15min, 30min, or 45min per hour; continuous operation also possible
  • Power-off Memory: Unit retains its operating status prior to power outage upon restart
  • Frost Protection: Unit enters frost protection mode when outdoor temperature is too low
Engineering Mode
  • Allows free adjustment of fan speeds for supply and exhaust air at each speed level
Advanced Functions
  • Ultra-Low Temperature Operation: Can operate normally (intermittently) even below 5°F (-15°C)
  • Temperature Calibration: Displays and calibrates 3 air temperatures (fresh air, return air, supply air); all 3 temperatures used in intelligent control
  • Advanced Sleep Mode: Operates at lowest speed during specific periods, intelligently opens or closes bypass based on indoor-outdoor temperature difference to reduce air conditioning energy consumption
  • Intelligent Airflow Compensation: Intelligently compensates airflow after prolonged operation without replacing or cleaning filters or the core
Pre-configured Functions
  • Cloud Control: Remote control via Tuya Cloud platform mobile APP (WiFi module required)
  • Forced Dehumidification: Set desired indoor humidity for intelligent operation (humidity sensor required)
  • CO2 Forced Ventilation: Intelligent operation based on preset CO2 control logic (CO2 sensor required)
  • Differential Pressure Filter Alert: Intelligent operation and alerts based on core and filter differential pressure (differential pressure switch required, must be installed at factory)
  • Multiple Signal Interfaces: RS485 interface, bypass control switch signal, differential pressure signal, forced start/stop signal, fire alarm signal, forced high-speed input signal, fault signal, operation signal, and electric heating signal
Optional Keypad Controller Functions (HDK-CK23C3)
Basic Functions
  • Heat Exchange Mode: Energy from exhaust air can be extracted to heat (in winter) or cool (in summer) the fresh air, reducing energy consumption
  • Speed Adjustment: One-touch high speed for supply/exhaust air and one-touch exit from high speed mode
  • Operation Timer: One-touch high speed duration: 10/20/30 minutes
  • Power-off Memory: Unit retains its operating status prior to power outage upon restart
  • Frost Protection: Unit enters frost protection mode when outdoor temperature is too low
Advanced Function
  • Ultra-Low Temperature Operation: Unit can operate normally (intermittently) even below 5°F (-15°C)
Pre-configured Functions
  • Multiple Signal Interfaces: RS485 interface, bypass control switch signal, differential pressure signal, forced start/stop signal, fire alarm signal, forced high-speed input signal, fault signal, operation signal, and electric heating signal
Controller Compatibility Note: Controller products are classified into Level 1 and Level 2 based on functionality. The keypad controller HDK-CK23C3 is a Level 2 controller. The keypad controller HDK-CK23C2 and the intelligent fresh air controller HDK-CK23C1 are both Level 1 controllers. Compatibility rules: A Level 2 controller can coexist with either of the two Level 1 controllers without conflict. However, the two Level 1 controllers cannot be used simultaneously; only one must be selected.
Optional Components List
Basic Controller and Sensors
No.DescriptionModel
1Basic ControllerHDK-CK23C2
2Controller Connection CableLJX-CK22C/5M(W)
3DC Control BoardPCB-CK23C
4Supply Air Temperature SensorHDK-CK-T-0.5M-W
5Return Air Temperature SensorHDK-CK-T/2M (Red)
6Fresh Air Temperature SensorHDK-CK-T/3M (Green)
Optional Electrical Control Components
No.DescriptionModelPart Code
1Intelligent Fresh Air ControllerHDK-CK23C1C01318000029
2Level 2 ControllerHDK-CK23C3C01318000030
3CO₂ SensorHDK-CK-CO2/5M(B)-F1C01318000025
4Humidity SensorHDK-CK-HT2/5M(W)C01318000024
5Differential Pressure Switch609.010+1001C01318000008
6WiFi ModuleHDK-CK-WIFIC01318000009
Product Features
Air Temperature Sensor And Residential ERV HRV equipment engineered to optimize indoor air exchange and reduce energy waste in residential buildings 0Air Temperature Sensor And Residential ERV HRV equipment engineered to optimize indoor air exchange and reduce energy waste in residential buildings 1Air Temperature Sensor And Residential ERV HRV equipment engineered to optimize indoor air exchange and reduce energy waste in residential buildings 2Air Temperature Sensor And Residential ERV HRV equipment engineered to optimize indoor air exchange and reduce energy waste in residential buildings 3