> Actualités de l'entreprise HOLTOP Water-Cooled DX HVAC System Deployed at 203 MW Zhonglian Thailand Rayong Data Center

HOLTOP Water-Cooled DX HVAC System Deployed at 203 MW Zhonglian Thailand Rayong Data Center

2026-10-09

Dernières nouvelles de l'entreprise sur HOLTOP Water-Cooled DX HVAC System Deployed at 203 MW Zhonglian Thailand Rayong Data Center

Rooftop-integrated water-cooled DX air handling units support ±2°C / ±10% RH control, tropical corrosion resistance and remote O&M for AI/HPC infrastructure.

dernières nouvelles de l'entreprise HOLTOP Water-Cooled DX HVAC System Deployed at 203 MW Zhonglian Thailand Rayong Data Center  0

RAYONG, Thailand — HOLTOP has deployed its water-cooled direct expansion (DX) air handling solution at the Zhonglian Thailand Rayong Data Center, a planned 203 MW AI and computing campus in Thailand’s Eastern Economic Corridor (EEC).

The project is invested and operated by Stratus Technology, a subsidiary of China Zhonglian Data Group. It supports general IDC colocation, cloud hosting, AI large-model and HPC workloads, and cross-border enterprise/government line transit.

For AI and high-density racks, the facility requires continuous heat removal and room-level control within ±2°C and ±10% RH. It also requires 7*24 high-load energy efficiency and remote operation and maintenance (O&M) to reduce overseas site costs.

dernières nouvelles de l'entreprise HOLTOP Water-Cooled DX HVAC System Deployed at 203 MW Zhonglian Thailand Rayong Data Center  1

HOLTOP’s solution uses rooftop-integrated water-cooled DX air handling units (AHUs). The design eliminates a dedicated indoor AHU room, applies rain and corrosion protection for tropical storms and coastal salt spray, and requires only ductwork connection before commissioning.

Precision control is achieved through high-precision sensors and intelligent control algorithms that respond to load changes and help avoid local hot spots and temperature/humidity fluctuations.

For air quality, the units provide pre-treated fresh air and chemical filtration for sulfur- and nitrogen-based compounds. Treated air meets the ISA S71.04 G1 severity level for gas-phase corrosion.

dernières nouvelles de l'entreprise HOLTOP Water-Cooled DX HVAC System Deployed at 203 MW Zhonglian Thailand Rayong Data Center  2

The water-cooled heat rejection architecture is less affected by outdoor dry-bulb temperature than air-cooled systems, supporting stable condensing conditions and efficient operation in Thailand’s hot climate. This helps reduce system Power Usage Effectiveness (PUE) under 7*24 high-load operation.

The smart management system collects operating status, control parameters and energy data, and supports remote monitoring, alarm notifications, multi-unit cluster control and automatic logs. This reduces on-site inspections and simplifies troubleshooting for overseas teams.

The project validates HOLTOP’s delivery capability for high-precision, energy-efficient HVAC in tropical, high-humidity AI data centers.

dernières nouvelles de l'entreprise HOLTOP Water-Cooled DX HVAC System Deployed at 203 MW Zhonglian Thailand Rayong Data Center  3

Technical Snapshot
Item Specification
System type Water-cooled DX AHU, rooftop integrated
Application AI/HPC high-density data center
Campus planned capacity 203 MW
Control target ±2°C; ±10% RH (project design target)
Air quality Chemical filtration; ISA S71.04 G1
Heat rejection Water-cooled
Installation Rooftop; no dedicated indoor AHU room; rain/salt-spray protection
Operation 7*24 continuous high-load
O&M Remote monitoring, alarms, cluster control, operation logs
Configuration Project-specific; capacity, refrigerant, filtration stages and redundancy available on request

Note: Control performance is project-specific and depends on load profile, zoning, sensor placement and commissioning.

dernières nouvelles de l'entreprise HOLTOP Water-Cooled DX HVAC System Deployed at 203 MW Zhonglian Thailand Rayong Data Center  4

About HOLTOP
HOLTOP provides air handling and HVAC solutions for data centers and mission-critical facilities, focusing on energy efficiency, precision control and intelligent operation.

Media Contact
Nancy Yin
nancy@holtop.com.cn
https://holtopinternational.com

To discuss data center HVAC requirements, contact HOLTOP.