Holtop DC Inverter Air Conditioners DX Coil Air Handling Units 8000 m³/h

Holtop DC Inverter Air Conditioners DX Coil Air Handling Units 8000 m³/h

製品詳細:
起源の場所: 中国、北京
ブランド名: Holtop
証明: CE
モデル番号: HZN-15KCZ1-Y-DC-BZ & HFM-15HA1-DC
詳細情報
起源の場所:
中国、北京
ブランド名:
Holtop
証明:
CE
モデル番号:
HZN-15KCZ1-Y-DC-BZ & HFM-15HA1-DC
屋内単位モデル:
HZN-15KCZ1-Y-DC-BZ
屋外ユニットモデル:
HFM-15HA1-DC
公称冷却能力(kw):
33.8
公称暖房能力(kw):
37.9
電源:
380V/3PH/50Hz
室内機風量(m3/h):
8000
室外機冷却電力入力(KW):
10.21
室外機 室外機(KW):
10.42
冷媒:
R410A
ハイライト:

High Light

ハイライト:

Holtop DC inverter air conditioner AHU

,

DX coil air handling unit 8000 m³/h

,

inverter air conditioner with DX coil

取引情報
最小注文数量:
1個
価格:
交渉可能
パッケージの詳細:
受渡し時間:
2週間
支払条件:
TT
供給の能力:
年間200,000ユニット
製品の説明

      Adopt a number of leading technologies to build a more powerful, stable and efficient cooling system.
     Innovative noise reduction technology minimizes the operating noise of indoor and outdoor machines and creates a quiet environment.
         New shell design, better stability and better appearance.
 

Products Detail


Holtop DC Inverter Air Conditioners DX Coil Air Handling Units 8000 m³/h 0


     Holtop DC DX Air Handling Unit includes DC Inverter DX air conditioner outdoor unit and constant frequency DX air conditioner outdoor unit these two series.

     The capacity of DC inverter DX AHU is 10-20P, while the capacity of constant frequency DX AHU is 5-18P.

     On the basis of constant frequency DX AHU, the newly developed DC inverter DX AHU adopts the enhanced vapor injection technology to open a new era of low-temperature heating.

     The new design of air-conditioning system and self-developed control program give full play to product performance and bring users a more comfortable air-conditioning experience.

Item/Series DC Inverter Series Constant Frequency Series
Cooling capacity (kw) 25 – 509 12 – 420
Heating Capacity (kw) 28 – 569 18 – 480
Airflow (m3/h) 5500 – 95000 2500 – 80000
Frequency Range of Compressor (Hz) 20 – 120 /
Max. length of Pipe (m) 70 50
Max. Drop (m) 25 25
Operating Range Cooling Outdoor DB temperature (°C) -5-52 15 – 43
Indoor WB temperature (°C) 15 – 24 15 – 23
Heating Indoor DB temperature (°C) 15 – 27 10-27
Outdoor WB temperature (°C) -20 – 27 -10-15


Indoor Unit

  • Heat Exchangers: There are cross-flow total heat exchangers, cross-flow plate heat exchangers or rotary heat exchangers to choose from to meet the different needs of customers.

Holtop DC Inverter Air Conditioners DX Coil Air Handling Units 8000 m³/h 1


2.PM2.5 solution

1)High Efficiency To Remove The Haze
      Equipped with a high-efficiency filter element, which can effectively remove PM2.5 particles carried in the air, ensuring that the outdoor air entering the indoor air is clean.


Holtop DC Inverter Air Conditioners DX Coil Air Handling Units 8000 m³/h 2


3. Indoor formaldehyde removal solution

      The indoor unit can be added with a formaldehyde removal module to effectively filter and decompose formaldehyde molecules; coupled with the replacement and dilution of heat exchangers and filters, double removal of formaldehyde.


Holtop DC Inverter Air Conditioners DX Coil Air Handling Units 8000 m³/h 3


4. Bring fresh outdoor air
      With this AHU, fresh outdoor air will be brought into the room. By increasing the oxygen concentration, reducing carbon dioxide, removing odors and other harmful gases, the indoor air quality is greatly improved.


Outdoor Unit

      STRUCTURAL FEATURES OF THE TOP DISCHARGE OUTDOOR UNIT


Holtop DC Inverter Air Conditioners DX Coil Air Handling Units 8000 m³/h 4


      STRUCTURAL FEATURES OF SIDE DISCHARGE OUTDOOR UNIT


Holtop DC Inverter Air Conditioners DX Coil Air Handling Units 8000 m³/h 5